1. Product-Specific Details

1.1 Specifications and Parameters

H03V2V2-F and H03V2V2h2-F ground cables are engineered with precise technical specifications to meet the rigorous safety and performance requirements of low-voltage grounding systems. These parameters ensure reliable fault current dissipation, durability, and compliance with European standards (EN 50525).
Conductor Specifications
The core of these cables features stranded Copper Conductors, optimized for conductivity and Flexibility:
  • Cross-Sectional Area: The "03" in the designation corresponds to a nominal cross-sectional area of 0.5 mm², with a tolerance of ±0.05 mm². This size is tailored to handle typical fault currents in low-voltage systems (up to 16A for short durations, as specified in EN 60898).

  • Stranding Configuration: Conductors are composed of 16 strands of 0.20 mm diameter Copper Wire, twisted in a concentric lay pattern with a lay length of 12–18 mm. This stranding enhances flexibility, allowing the cable to bend around radii as small as 10 mm (5x the conductor diameter) without damaging the insulation—critical for routing through tight wall cavities or conduits.

  • Conductivity and Resistance: High-purity electrolytic copper (99.9% purity) ensures a conductivity of 58 MS/m at 20°C. The DC resistance at 20°C is ≤36.1 Ω/km, ensuring minimal voltage drop during fault conditions, which is essential for effective grounding.

Insulation and Jacketing Parameters
  • Inner Insulation: Each conductor is insulated with PVC (polyvinyl chloride) of 0.3 mm thickness, with a dielectric strength of ≥15 kV/mm. This insulation is rated for continuous operation at 70°C and short-term exposure to 105°C during faults, preventing electrical breakdown.

  • Outer Insulation/Jacket: The "V2V2" designation indicates a double insulation structure: an inner layer enclosing individual conductors and an outer jacket covering all cores. The outer jacket is 0.5 mm thick (for round cables) or 0.4 mm thick (for Flat Cables) and made of flame-retardant PVC complying with EN 60332-1-2 (vertical flame test).

  • Halogen-Free Variant (H03V2V2h2-F): The "h2" specifies a halogen-free PVC formulation, with halogen content ≤0.5% by weight. This reduces toxic gas emission (e.g., hydrogen chloride) during combustion to ≤5 mg/g, meeting EN 60754-1 standards—critical for enclosed spaces like hospitals or high-rise apartments.

Physical Dimensions
  • Round Cable: Cylindrical profile with an outer diameter of 3.2 ±0.2 mm. This compact size allows easy installation in 6 mm diameter conduits, common in European electrical systems.

  • Flat Cable: Rectangular profile measuring 6.0 mm (width) × 1.8 mm (thickness) ±0.2 mm. The slim design enables installation under carpets or between floorboards without protruding, with a thickness that avoids damage from foot traffic.

Voltage and Safety Ratings
  • Rated Voltage: 300/300V (phase-to-earth/phase-to-phase), suitable for low-voltage systems up to 250V AC (common in residential and commercial settings).

  • Flame Retardancy: Both variants pass EN 60332-1-2, self-extinguishing within 60 seconds of removing the flame source.

  • Environmental Resistance: The PVC Jacket is resistant to:

    • Moisture (IPX4 rating, protected against splashing water).

    • UV radiation (suitable for protected outdoor use, e.g., under eaves).

    • Chemicals (resistant to mild acids, alkalis, and mineral oils per EN 50396).

1.2 Unique Applications

H03V2V2-F and H03V2V2h2-F ground cables are designed for specific grounding scenarios, leveraging their flexibility, safety features, and form factors to address diverse installation needs.
Residential Grounding Systems
  • Appliance Grounding: Used to ground household appliances (refrigerators, washing machines, ovens) via their power cords. The 0.5 mm² conductor safely diverts fault currents from damaged insulation to earth, preventing electric shock. Round cables are preferred for new builds, as they fit neatly into the 3-core power cords (live, neutral, ground) required by EN 60794.

  • Outlet and Lighting Grounding: In modern homes, these cables connect power outlets and light fixtures to the main grounding busbar. Flat cables are ideal for retrofits, as they can be routed under carpets or behind baseboards in existing rooms without major renovations. The green/yellow color-coded insulation (per IEC 60446) ensures easy identification, reducing installation errors.

Commercial and Public Buildings
  • Office Spaces: Grounding IT equipment (computers, servers, printers) and HVAC systems. The halogen-free H03V2V2h2-F variant is mandated in many European offices, as it minimizes smoke and toxic fumes in case of fire, aiding evacuation and reducing damage to sensitive electronics.

  • Retail and Hospitality: Used in cash registers, security cameras, and kitchen equipment. The flat cable’s slim profile is advantageous in retail spaces, where it can be hidden under display units or floor mats without disrupting customer flow.

  • Healthcare Facilities: Hospitals and clinics rely on H03V2V2h2-F for grounding medical devices (e.g., MRI machines, patient monitors). The halogen-free insulation reduces the risk of respiratory hazards during fires, protecting patients and staff.

Light Industrial Settings
  • Workshop Machinery: Grounding power tools (drills, saws) and small-scale industrial equipment. The round cable’s durability withstands occasional abrasion from tools or debris, while its flexibility allows routing around machinery without kinking.

  • Control Panels: Connecting control systems (PLCs, sensors) to earth electrodes. The double insulation ensures reliable performance in dusty environments, preventing insulation degradation that could compromise grounding integrity.

1.3 Materials and Construction

The materials used in H03V2V2-F and H03V2V2h2-F cables are carefully selected to balance safety, durability, and performance, with each component serving a critical role in grounding functionality.
High-purity electrolytic copper is sourced from certified suppliers (ISO 9001) to ensure minimal impurities. The copper undergoes annealing (heating to 600°C and slow cooling) to soften the metal, enhancing ductility for stranding. This process reduces brittleness, ensuring the strands resist breakage during bending or installation.
PVC Insulation and Jacketing
  • Standard PVC (H03V2V2-F): Formulated with:

    • PVC resin (80% by weight) for structural integrity.

    • Phthalate plasticizers (15%) to enhance flexibility.

    • Flame retardants (5%, e.g., antimony trioxide) to meet EN 60332-1-2.

  • Halogen-Free PVC (H03V2V2h2-F): Replaces halogenated flame retardants with aluminum hydroxide (20% by weight), which releases water vapor during combustion to suppress flames, reducing toxic emissions.

Both formulations include stabilizers (calcium-zinc compounds) to prevent degradation from heat and UV exposure, extending the cable’s lifespan to 20+ years in typical environments.
Color Coding
Insulation is colored green/yellow (1:1 ratio stripes) per IEC 60446, ensuring universal recognition as a grounding conductor. This prevents accidental connection to live or neutral circuits, a critical safety measure during installation.

1.4 Production Process

Manufacturing H03V2V2-F and H03V2V2h2-F cables involves precision engineering to ensure consistency and compliance with EN 50525. Each step is monitored via quality control checks to maintain specifications.
Conductor Stranding
  • Copper wire rods (8 mm diameter) are drawn down to 0.20 mm diameter using diamond dies, ensuring uniform thickness.

  • 16 strands are twisted in a stranding machine with computer-controlled lay length (12–18 mm) to achieve the required flexibility.

  • Stranded Conductors undergo a final annealing step to relieve stress, ensuring they retain flexibility after installation.

Insulation Extrusion
  • Individual conductors are fed into an extrusion line, where molten PVC (180–200°C) is applied to form the inner insulation (0.3 mm thickness).

  • Laser gauges monitor insulation thickness, with automatic adjustments to the extrusion rate to maintain tolerance within ±0.02 mm.

  • Insulated Conductors are cooled in a water bath (20–25°C) to solidify the PVC, then dried to prevent moisture retention.

Cable Assembly
  • For round cables: Insulated conductors are twisted together in a bunch lay pattern (lay length 30–40 mm) to form a core, then passed through a second extrusion machine to apply the outer jacket (0.5 mm thickness).

  • For flat cables: Insulated conductors are laid parallel on a conveyor belt, with outer jacket PVC extruded over them in a flat die, forming the rectangular profile. The flat shape is maintained using cooling rollers set to 6.0 mm × 1.8 mm dimensions.

Quality Testing
Each production batch undergoes rigorous testing:
  • Resistance Test: DC resistance measured using a micro-ohmmeter to ensure it meets ≤36.1 Ω/km.

  • Flame Test: 500 mm cable samples are subjected to EN 60332-1-2, with flame application for 60 seconds; cables must self-extinguish within 60 seconds.

  • Dielectric Strength: Insulation is tested with 2 kV AC for 1 minute (round cables) or 1.5 kV AC for 1 minute (flat cables) with no breakdown.

  • Halogen Emission (H03V2V2h2-F): EN 60754-1 testing measures acid gas emission, ensuring it remains ≤5 mg/g.

2. Product General Information

2.1 Packaging

Packaging is designed to protect cables during storage and transportation while facilitating easy handling for installers.
Reel Packaging
  • Standard Reels: Cables are wound onto 300 mm diameter cardboard reels (for 50m and 100m lengths) or 400 mm diameter plastic reels (for 500m lengths). Reels feature flanges to prevent unwinding and a central core (50 mm diameter) for mounting on dispensing stands.

  • Labeling: Each reel is labeled with:

    • Cable type (H03V2V2-F or H03V2V2h2-F).

    • Length (50m, 100m, 500m).

    • Conductor size (0.5 mm²).

    • Standards compliance (EN 50525, CE marking).

    • Batch number and production date for traceability.

  • Protective Layer: Cables are wrapped in LDPE (low-density polyethylene) film to prevent dust and moisture ingress, with a moisture indicator (blue-to-pink) to alert to water exposure during storage.

Bulk Packaging
  • For large orders (e.g., 1000m+), cables are supplied in wooden drums (600 mm diameter) with steel reinforcing rings, suitable for palletized transport. Drums include a sealed plastic liner to protect against humidity.

Custom Packaging
Manufacturers offer custom options for wholesale clients:
  • Branded reels with company logos.

  • Pre-cut lengths (e.g., 5m, 10m) in poly bags for retail sale.

  • Color-coded reel flanges to distinguish between round/flat or halogen-free variants.

2.2 Transportation

Transportation protocols ensure cables arrive undamaged, with protection against physical stress and environmental factors.
Mode of Transport
  • Road Transport: For European deliveries, enclosed trucks with temperature-controlled trailers (15–25°C) are used to prevent PVC degradation from extreme heat or cold. Cables are secured with straps to pallets, with edge protectors to avoid reel damage.

  • Sea Freight: For international shipments, reels are packed into 20ft or 40ft containers, with dunnage (wooden blocks) to prevent shifting during transit. Desiccants are placed in containers to control humidity (≤60% RH) and protect against moisture.

  • Air Freight: Urgent orders (e.g., replacement cables for construction delays) are shipped via air, with reels packed in shock-absorbent foam to withstand turbulence.

Handling Guidelines
  • Reels must be lifted using forklifts or cranes with spindle attachments, avoiding damage to flanges. Dragging reels is prohibited, as it can unwind the cable or damage the jacket.

  • Temperature restrictions: Cables must not be exposed to temperatures below -5°C (to prevent PVC cracking) or above 40°C (to avoid insulation softening) during transport.

2.3 Shipping and Delivery

Efficient shipping processes ensure timely delivery with clear communication and documentation.
Order Processing
  • Orders are processed within 24 hours of receipt, with confirmation sent via email including:

    • Order details (quantity, type, length).

    • Estimated dispatch date.

    • Tracking number (once shipped).

  • For custom lengths or large volumes (5000m+), production lead times are 5–7 business days, with regular updates provided to clients.

Tracking and Notification
  • Clients receive a tracking link via email, allowing real-time monitoring of shipment location and estimated delivery time (powered by carriers like DHL, UPS, or DB Schenker).

  • Automated notifications alert clients when the shipment is:

    • Dispatched from the factory.

    • Arrived at a regional hub.

    • Out for delivery (with a 2-hour window for residential/commercial drop-offs).

Delivery Inspection
  • Upon delivery, clients are advised to inspect reels for:

    • Damage to flanges or core.

    • Tears in the LDPE protective film.

    • Moisture indicators showing pink (signaling water exposure).

  • Any damage must be reported within 48 hours, with photos required for claims processing. Manufacturers coordinate with carriers to arrange replacements for damaged goods at no cost.

2.4 Samples

Providing samples allows clients to verify cable quality and compatibility before placing bulk orders.
Sample Availability
  • Standard samples are 1m lengths of H03V2V2-F (round and flat) and H03V2V2h2-F (round and flat), supplied free of charge to qualified clients (e.g., electrical contractors, building developers).

  • Custom samples (e.g., specific lengths or branded labeling) are available for a fee (€10–€20), refundable with subsequent orders over €1000.

Sample Request Process
  • Clients request samples via the manufacturer’s website, email, or sales team, specifying:

    • Cable type (H03V2V2-F or H03V2V2h2-F).

    • Form (round or flat).

    • Quantity.

    • Delivery address.

  • Samples are dispatched within 2 business days via express post, with tracking provided.

Testing Support
  • Samples include a test report summarizing key parameters (resistance, flame retardancy, dielectric strength) for client verification. Manufacturers also assist with third-party testing (e.g., via SGS or TÜV) at cost, if required for project compliance.

2.5 After-Sales Service

Comprehensive after-sales support ensures client satisfaction and addresses any post-purchase issues.
Technical Support
  • A team of electrical engineers provides guidance via phone, email, or video call on:

    • Installation best practices (e.g., minimum bending radii, termination methods).

    • Compliance with local codes (e.g., German DIN 18015 for building grounding).

    • Troubleshooting (e.g., high resistance in grounding loops).

  • Response times: 4 hours for urgent queries, 24 hours for standard requests.

Warranty
  • Standard warranty: 10 years from purchase, covering defects in materials or workmanship (e.g., insulation cracking, conductor breakage under normal use).

  • Warranty claims require:

    • Proof of purchase.

    • Photos/videos of the defect.

    • Installation details (to rule out improper handling).

  • Valid claims result in free replacement cables or a full refund, with expedited shipping for critical applications (e.g., hospital renovations).

Feedback and Improvement
  • Clients are surveyed post-purchase to rate:

    • Cable performance (flexibility, durability).

    • Packaging quality.

    • Delivery timeliness.

  • Feedback is used to refine production processes—for example, adjusting PVC formulations to enhance cold-weather flexibility based on Nordic client input.

In conclusion, H03V2V2-F and H03V2V2h2-F ground cables combine precision engineering, safety compliance, and practical design to meet the demands of modern grounding systems. From their optimized conductor and insulation specifications to robust packaging and responsive after-sales support, every aspect is tailored to ensure reliable, safe performance in residential, commercial, and light industrial environments. Whether in round or flat form, these cables are a trusted choice for ensuring electrical safety and system integrity.
En savoir plus sur les produits câblés
Contactez Hongtai Cable Technology Co., Ltd
Contactez-nous

Hongtai Cable Technology Co., Ltd

E-mail: export@qlcables.com

           sales@qlcables.com

Tel / WhatsApp: + 86-18032066271

Ajouter: Zone de développement industriel de Xiaokou, comté de Ningjin, City de Xingtai , Province de Hebei, Chine

Copyright © Hongtai Cable Technology Co., Ltd  Support technique:Technologie Ronglida


Plan du site

Ce site Web utilise des cookies pour vous garantir la meilleure expérience sur notre site Web.

Accepter rejeter