Structural Integration: Combines Power Conductor, insulation, and mechanical support into a single unit, eliminating:
Separate messenger wires (reducing material costs by 35%)
Spacer hardware (simplifying inventory management)
Additional installation steps (cutting project timelines by 40%)
Layer Configuration: From core to exterior:
Aluminum Alloy Conductor (1X35 to 1X120mm²)
Semi-conductive screen (0.5mm thickness)
XLPE insulation (3.4mm thickness)
Semi-conductive outer screen (0.3mm thickness)
Weatherproof PE jacket (1.2mm thickness, UV-stabilized)
Self-Supporting Mechanism: The 6201-T81 aluminum alloy conductor provides 180MPa tensile strength, enabling 100-meter spans with <2.5m sag at 90°C. This exceeds the capabilities of traditional Insulated Conductors by 60% in span length.
Aerodynamic Profile: 18–28mm outer diameter (depending on size) reduces wind load by 25% compared to conductor-messenger combinations, minimizing stress on utility poles during storms with winds up to 120kph.
Alloy Composition: Aluminum with magnesium and silicon additives (Mg: 0.5–0.9%, Si: 0.7–1.1%) creates a heat-treatable alloy that, when processed to T81 temper, delivers:
52% IACS conductivity (optimal for high-voltage applications)
180MPa tensile strength (30% higher than 1350-H19 aluminum)
Superior creep resistance (critical for maintaining tension in long spans)
Strand Configuration: Each conductor comprises 19 strands (for 35–70mm²) or 37 strands (for 95–120mm²) of 1.2–2.0mm diameter, twisted at 16× lay length. This stranding:
Enhances Flexibility (bend radius 12× outer diameter) for installation around obstacles
Reduces "skin effect" by 20% at 50–60Hz compared to solid conductors
Improves resistance to fatigue from wind-induced vibration
Size-Specific Performance:
1X35mm²: 130A continuous at 90°C, 1.2kg/m weight
1X50mm²: 165A continuous at 90°C, 1.6kg/m weight
1X70mm²: 205A continuous at 90°C, 2.0kg/m weight
1X95mm²: 250A continuous at 90°C, 2.4kg/m weight
1X120mm²: 290A continuous at 90°C, 2.8kg/m weight
XLPE Cross-Linking: Peroxide cross-linking creates a three-dimensional polymer network that:
Withstands 35kV AC without breakdown (10kV/mm dielectric strength)
Operates continuously at 90°C (130°C short-term overload)
Resists water treeing (a common failure mode in humid environments)
Temperature Performance: -40°C to 90°C continuous operation, with:
No embrittlement at low temperatures (passes -40°C impact test)
No insulation flow at high temperatures (maintains dimensional stability)
Consistent dielectric properties across the entire range
Semi-Conductive Screens: Inner and outer semi-conductive layers:
Ensure uniform electric field distribution around the conductor
Eliminate partial discharge (a major cause of insulation degradation)
Bond chemically to XLPE for seamless layer transitions
Weather Protection: 1.2mm PE jacket with 2.0% carbon black content:
Blocks 99% of UV radiation (retaining 90% tensile strength after 20,000 hours of sunlight)
Resists ozone degradation (critical in industrial areas)
Withstands salt spray (up to 5% NaCl concentration for coastal applications)
Voltage Ratings:
20kV: 11.5kV phase-to-ground, 20kV phase-to-phase
35kV: 20.2kV phase-to-ground, 35kV phase-to-phase
Current-Carrying Capacity:
Dielectric Loss: <0.001 at 50Hz, minimizing energy waste in long-distance transmission.
Partial Discharge: <10pC at 1.73× rated voltage, ensuring long-term insulation integrity.
Short-Circuit Withstand: 25kA for 2 seconds, providing ample time for protective relays to clear faults.
Primary distribution from substations to industrial areas
Rural electrification projects requiring long spans
Urban network modernization where space is limited
Industrial park high-voltage feeders
Tensile Strength: 180MPa for the aluminum alloy conductor, with:
1X35mm²: 6.3kN breaking force
1X50mm²: 9.0kN breaking force
1X70mm²: 12.6kN breaking force
1X95mm²: 17.1kN breaking force
1X120mm²: 21.6kN breaking force
Span Capability: 100-meter maximum span with:
<2.5m sag at 90°C (1X120mm²)
<3.0m sag at 90°C (1X35mm²)
River crossings
Valley spans
Highway intersections
Protected environmental areas
Wind and Ice Loading: Withstands:
120kph wind speeds (equivalent to category 1 hurricane)
10mm radial ice accumulation (adding 1.8–3.2kg/m depending on size)
Combined wind-ice loads per IEC 60826
Impact Resistance: Survives 100J impact (10kg weight dropped from 1m) without conductor damage, ensuring durability during installation and storm events.
Handling Advantages: Despite its high-voltage capabilities, the cable remains manageable:
1.2–2.8kg/m weight (60% lighter than copper alternatives)
Flexible stranding allows bending to 12× outer diameter
Available on 500-meter reels (reducing splice requirements)
Installation Sequence: Simplified 5-step process:
Unreel cable from transport reel to installation reel
Pull cable between poles using winch (maximum 30% of breaking force)
Secure ends to pole-mounted terminations
Apply tension using dynamometer (preset to design tension)
Install anti-vibration dampers (where required)
Termination Systems: Compatible with:
Outdoor Cable terminations (20kV/35kV rated)
Polymer insulators (reducing weight on poles)
Load-break elbows (for sectionalizing)
Junction boxes (for tap-offs to lower voltage)
Specialized Equipment: Requires only:
Tension-controlled winch (5kN capacity)
Cable stripper for multi-layer insulation
Crimping tools for Aluminum Alloy Conductors
Dynamometer for tension verification
Crew Requirements: 3-person crew can install:
300 meters of 1X35mm² per day
200 meters of 1X120mm² per day
IEC 60502-2: Specification for Power Cables with rated voltages from 6kV to 30kV
ASTM B800: Standard for 6201 aluminum alloy Electrical Conductors
IEC 60826: Calculation of load capacity of Overhead Lines
ANSI/ICEA S-97-682: Specifications for high-voltage aerial cables
EN 50182: European standard for overhead Power Cables
Urban Networks: Ideal for cities where:
Limited right-of-way requires long spans
Aesthetic concerns favor single-cable solutions
Reliability is critical (minimizing outage costs)
Space constraints limit pole installation
Rural Electrification: Transforms connectivity in remote areas by:
Spanning rivers and valleys without intermediate poles
Reducing infrastructure requirements in low-population areas
Withstanding extreme weather with minimal maintenance
Lowering total project costs by 35% compared to traditional systems
Industrial Feeders: Powers manufacturing facilities requiring:
High reliability (minimizing production downtime)
Long runs between substations and plant entrances
Resistance to industrial contaminants
Ability to handle load fluctuations
Specialized Environments: Thrives in challenging locations:
Coastal areas (salt spray resistance)
Desert regions (extreme temperature tolerance)
Forested areas (reduced clearance requirements)
Protected habitats (minimizing pole footprint)
Initial Cost Savings:
35% lower material costs than conductor-messenger combinations
40% reduced installation labor
60% fewer poles required for 100-meter spans
Lifecycle Savings: 30-year service life minimizes:
Replacement frequency (once vs. 2–3 times for 12-year cables)
Maintenance costs (inspection every 5 years vs. annual for bare conductors)
Downtime costs (estimated at $10,000/hour for industrial feeders)
Energy Efficiency: 52% IACS conductivity reduces line losses by 8% compared to lower-grade aluminum, saving:
1X35mm²: ~5,200kWh annually per 100 meters
1X120mm²: ~18,500kWh annually per 100 meters
Environmental Benefits: Reduced pole requirements save 10–15 trees per kilometer, while longer spans minimize habitat disruption.
Service Life: 30 years under normal conditions, with:
25-year expectancy in coastal/salt environments
20-year expectancy in heavy industrial areas
Inspection Requirements:
Visual inspection every 5 years (looking for:
UV degradation of jacket
Damaged dampers
Proper tension retention
Hardware corrosion)
Thermal imaging every 10 years (identifying hot spots at terminations)
No periodic cleaning or treatment required
Repair Capabilities:
Damaged sections can be spliced using 20kV/35kV rated joints
Jacket repairs possible with heat-shrink sleeves
Partial replacement feasible without full span removal
Repair costs 60% lower than full span replacement
End-of-Life Management:
Aluminum alloy retains 90% of material value for recycling
Insulation layers can be separated for material recovery
Complies with WEEE and RoHS directives for responsible disposal
Hongtai Cable Technology Co., Ltd
E-mail: export@qlcables.com
sales@qlcables.com
Tel / WhatsApp: + 86-18032066271
Ajouter: Zone de développement industriel de Xiaokou, comté de Ningjin, City de Xingtai , Province de Hebei, Chine
Copyright © Hongtai Cable Technology Co., Ltd Support technique:Technologie Ronglida
Ce site Web utilise des cookies pour vous garantir la meilleure expérience sur notre site Web.