325+116mm² Configuration: Three phase conductors (25mm² each) and one neutral conductor (16mm²), each comprising 7 strands of 2.1mm diameter 1350-H19 aluminum. This structure delivers:
110A continuous current (phase) at 90°C
70A continuous current (neutral) at 90°C
1.8kg total weight per meter (including insulation)
335+125mm² Configuration: Three phase conductors (35mm² each) and one neutral conductor (25mm²), each comprising 7 strands of 2.5mm diameter 1350-H19 aluminum, providing:
140A continuous current (phase) at 90°C
90A continuous current (neutral) at 90°C
2.2kg total weight per meter (including insulation)
Stranding Advantages: The 7-strand design with 12× lay length (12 times conductor diameter) offers:
Enhanced flexibility, allowing bending to 8× outer diameter (72mm for 325+116; 88mm for 335+125)
Reduced "skin effect" by 18% compared to solid conductors, ensuring efficient current distribution at 50–60Hz
Improved resistance to fatigue from thermal cycling and vibration, common in industrial environments
Material Properties: 1350-H19 aluminum alloy undergoes specialized annealing, achieving:
61% IACS conductivity for minimal power loss
174MPa tensile strength to withstand installation tensions
Natural oxide layer providing corrosion resistance in damp environments
Molecular Structure: Peroxide cross-linking creates a three-dimensional polymer network that:
Eliminates "cold flow" (insulation creep) at high temperatures
Increases dielectric strength to 24kV/mm, 35% higher than PVC
Reduces water absorption to <0.03% by weight, critical for damp locations
Temperature Performance: Continuous operation from -40°C to 90°C, with short-term overload capability up to 105°C. This range ensures reliability in:
Freezer facilities (-30°C)
Desert climates (45°C ambient)
Industrial areas with heat-generating equipment
Environmental Resistance:
UV stabilization (2.0% carbon black) retains 90% tensile strength after 15,000 hours of sunlight
Chemical Resistance to oils, solvents, and industrial cleaners
Resistance to fungi and bacterial growth in humid environments
Insulation Thickness: 1.5mm on phase conductors and 1.2mm on neutral conductors, exceeding IEC 60502 requirements to provide an extra margin of safety against:
Abrasion during installation
Mechanical damage in high-traffic areas
Rodent bites in commercial kitchens and warehouses
Voltage Rating: 0.6kV phase-to-ground, 1kV phase-to-phase, suitable for secondary distribution in:
Industrial plants
Commercial buildings
Infrastructure projects
Residential complexes
Voltage Drop:
325+116: <2.5% at full load over 50-meter runs
335+125: <2.0% at full load over 70-meter runs
Computer servers
Variable frequency drives
Medical devices
Precision manufacturing tools
Short-Circuit Handling: Withstands 20kA for 1 second, providing ample time for protective devices to clear faults before conductor damage occurs.
Impedance:
325+116: 0.58Ω/km at 60Hz
335+125: 0.41Ω/km at 60Hz
Tensile Strength:
325+116: 1,800N breaking force
335+125: 2,200N breaking force
Bend Radius:
Static (installation): 8× outer diameter
Dynamic (during operation): 12× outer diameter
Crush Resistance: Withstands 4kN/m² pressure without conductor damage, ensuring survival under:
Heavy equipment in industrial settings
Stacked materials in warehouses
Foot traffic when installed in floor ducts
Impact Resistance: Survives 50J impacts (5kg weight dropped from 1m) at -30°C without insulation cracking, a critical feature for cold-storage facilities.
Handling Benefits:
Flexible stranding allows easy pulling through conduits and cable trays
Color-coded insulation (brown/black/grey phases, blue neutral) simplifies phase identification
Uniform outer diameter ensures consistent performance in cable glands
Termination Process:
XLPE insulation strips cleanly with standard tools
Compatible with compression and mechanical lugs for 25mm² and 35mm² conductors
Termination time reduced by 25% compared to PVC-Insulated Cables
Installation Methods: Suitable for:
Conduit (PVC, steel, HDPE)
Cable trays (ladder, solid bottom)
Direct burial (with appropriate protection)
Aerial installation (with messenger support)
Crew Requirements: A 2-person crew can install:
500 meters of 325+116 per day
400 meters of 335+125 per day
IEC 60502-1: Specification for Power Cables with rated voltages up to 30kV
ASTM B230: Standard for aluminum Electrical Conductors
BS 6346: British standard for Power Cables for industrial applications
UL 44: Underwriters Laboratories standard for cross-linked polyethylene Insulated Cables
Industrial Facilities:
Manufacturing plants (machine tools, conveyor systems)
Warehouses (forklifts, lighting, HVAC)
Food processing (washdown areas, refrigeration)
Commercial Buildings:
Shopping malls (HVAC, escalators, retail units)
Office complexes (IT infrastructure, lighting, elevators)
Hotels (guest rooms, kitchens, laundry facilities)
Infrastructure Projects:
Transportation hubs (airports, railway stations)
Sports stadiums (lighting, scoreboards, concessions)
Healthcare facilities (medical equipment, life support systems)
Specialized Environments:
Cold storage (freezers, refrigerated warehouses)
Data centers (server racks, cooling systems)
Agricultural facilities (irrigation pumps, climate control)
Material Costs: 40% lower than equivalent Copper Cables, with comparable performance for low-voltage applications.
Installation Savings: 20% faster installation reduces labor costs, with a 500-meter project saving approximately $600.
Energy Efficiency: 61% IACS conductivity reduces line losses by 10% compared to lower-grade aluminum, saving:
325+116: $250–300 annually per 100 meters
335+125: $350–400 annually per 100 meters
Lifecycle Costs: 30-year service life minimizes replacement frequency, with maintenance limited to:
Visual inspections every 5 years
No periodic insulation treatments
Sustainability:
Aluminum is 100% recyclable with 95% energy savings vs. primary production
30-year service life reduces waste from replacements
Lead-free insulation complies with RoHS directives
Safety Features:
Flame-retardant XLPE insulation self-extinguishes within 30 seconds
Low smoke emission during combustion, improving evacuation conditions
Reduced risk of electric shock compared to unInsulated Conductors
Occupational Health:
No toxic fumes during normal operation
Resistant to mold growth, improving indoor air quality
Easy to handle without specialized protective equipment
Service Life: 30 years under normal conditions, with 25-year expectancy in harsh environments.
Inspection Requirements:
Visual checks for damage during scheduled shutdowns
Thermal imaging surveys every 10 years to identify hot spots
No periodic cleaning or treatment needed
Repair Options:
Damaged sections can be spliced using XLPE-compatible connectors
Insulation repairs possible with heat-shrink sleeves
Repair costs 70% lower than full cable replacement
End-of-Life Management:
Aluminum conductors retain 85% of material value as scrap
Insulation can be separated for recycling
Complies with WEEE directives for responsible disposal
Hongtai Cable Technology Co., Ltd
E-mail: export@qlcables.com
sales@qlcables.com
Tel / WhatsApp: + 86-18032066271
Ajouter: Zone de développement industriel de Xiaokou, comté de Ningjin, City de Xingtai , Province de Hebei, Chine
Copyright © Hongtai Cable Technology Co., Ltd Support technique:Technologie Ronglida
Ce site Web utilise des cookies pour vous garantir la meilleure expérience sur notre site Web.